  1. Products
  2. Automation technology - Voltage and Power Supply
  3. M12-K
  4. M12 Male angled connector, Contacts: 4+PE, 8.0-13.0 mm, unshielded, screw clamp, IP67, UL
Part no.: 99 0699 58 05

M12 Male angled connector, Contacts: 4+PE, 8.0-13.0 mm, unshielded, screw clamp, IP67, UL

M12-K, series 824, Automation Technology - Voltage and Power Supply
Compare product
Downloads
General features
Moreless
Part no. 99 0699 58 05
Connector design Male angled connector
Type standard DIN EN IEC 61076-2-111:2018-10;VDE 0687-76-2-111:2018-10
Version Connector pin angled
Connector locking system screw
Termination screw clamp
Degree of protection IP67
Cross-sectional area max. 1.50 mm² with ferrule / max. 2.50 mm² without ferrule / AWG 16 with wire-end ferrule / AWG 14 without wire-end ferrule
Cable outlet 8.0-13.0 mm
Twistability 72° (5 coding options)
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 46.11
Customs tariff number 85369010
Country of Origin DE
Rated voltage 630 V
Rated impulse voltage 6000 V
Rated impulse voltage UL 6000 V
Rated current 12.0 A
Insulation resistance > 1010 Ω
Pollution degree 3
Overvoltage category III
Insulating material group I
EMC compliance unshielded
Housing material PA
Contact body material PA (UL94 V-0)
Contact material CuZn (brass)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 3b3883bc-f901-493d-8ef7-9c16c0151544
eCl@ss 11.1 27-44-01-02
ETIM 9.0 EC002635
Low Voltage Directive 2014/35/EU (EN 60204-1:2018;EN 60529:1991)
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  6. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  7. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
  8. In the case of cable connectors with a metal threaded ring, it is imperative to ensure a connection with the PE protective contact of the appliance connector. Connecting cables between appliance connectors that are not connected to the PE contact are not permitted. The user must ensure a continuous connection of the protective earth conductor.
Downloads
Data sheet
Data sheet 99 0699 58 05
PDF
Data sheet, Data sheet 99 0699 58 05
Certificates
UL certificate
PDF, 1.05 MB
REACH
99 0699 58 05
PDF
RoHS
99 0699 58 05
PDF
China RoHS
99 0699 58 05
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment