Menu
Back
  1. Products
  2. Power connectors
  3. RD24 Power
  4. RD24 Male cable connector, Contacts: 3+PE, unshielded, moulded on the cable, IP67, PVC, black, 4 x 1.50 mm², 2 m
Part no.: 79 0231 20 04

RD24 Male cable connector, Contacts: 3+PE, unshielded, moulded on the cable, IP67, PVC, black, 4 x 1.50 mm², 2 m

RD24, series 692, Power Connectors
Available numbers of contacts
Compare product
Downloads
General features
Moreless
Part no. 79 0231 20 04
Connector design Male cable connector
Cable length 2 m (Standard 2 m and 5 m. Other lengths are available on request.)
Version Connector pin straight
Connector locking system screw
Termination moulded on the cable
Degree of protection IP67
Cross-sectional area 1.50 mm² / AWG 16
Temperature range from/to -25 °C / 80 °C
Mechanical operation > 500 Mating cycles
Weight (g) 269.00
Customs tariff number 85444290
Country of Origin DE
Rated voltage 400 V
Rated impulse voltage 6000 V
Rated current 16.0 A
Insulation resistance ≥ 1010 Ω
Pollution degree 3
Overvoltage category III
Insulating material group III
EMC compliance unshielded
Contact body material PA12
Contact material CuZn (brass)
Contact plating Ag (silver)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 0c711d29-3268-41f1-a0d5-840a23afa32b
eCl@ss 11.1 27-06-03-11
ETIM 9.0 EC002638
Low Voltage Directive 2014/35/EU (EN 60204-1:2018;EN 60529:1991)
RoHS Directive 2011/65/EU (EN 50581:2012)
Cable data
Moreless
Structure of the cable
Cable diameter 8.6 mm
Cross section 4 x 1.50 mm²
Sheath material PVC
Single-lead insulation PVC
Single-lead structure 28 x 0.25 mm
Cable color black
Mechanical properties
Bending radius, fixed cable ≥ 7.5 x Ø
Bending radius, moving cable ≥ 15 x Ø
Thermal properties
Temperature range cable in move from/to -5 °C / 80 °C
Temperature range cable fixed from/to -20 °C / 80 °C
Other features
Halogen free no
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 50 cNm).
Downloads
Data sheet
Data sheet 79 0231 20 04
PDF
REACH
79 0231 20 04
PDF
RoHS
79 0231 20 04
PDF
China RoHS
79 0231 20 04
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment
PDF
Declaration of conformity, RoHS Directive
Declaration of conformity
RoHS Directive
PDF
UKCA declaration of conformity, UK-RoHS
UKCA declaration of conformity
UK-RoHS
PDF
CAD files
Select required format
RD24 Power
79 0231 20 04