Menu
Back
  1. Products
  2. Miniature connectors
  3. Bayonet NCC
  4. Male cable connector, Contacts: 8, unshielded, solder, IP67, PUR, black, 8 x 0.25 mm², 2 m
Part no.: 77 6005 0000 50008-0200

Male cable connector, Contacts: 8, unshielded, solder, IP67, PUR, black, 8 x 0.25 mm², 2 m

Bayonet, series 770
Compare product
Downloads
General features
Moreless
Part no. 77 6005 0000 50008-0200
Connector design Male cable connector
Cable length 2 m
Version Connector pin straight
Connector locking system Bayonet
Termination solder
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 85 °C
Mechanical operation > 5000 Mating cycles
Weight (g) 260
Customs tariff number 85444290
Rated voltage 175 V
Rated impulse voltage 1750 V
Rated current (40 °C) 2.0 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 2
Overvoltage category II
Insulating material group II
EMC compliance unshielded
Housing material PUR
Contact body material PA
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material PA
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 7803ad67-87d8-449b-a9a2-ac3fedcf3d55
ETIM 9.0 EC002638
Cable data
Moreless
Structure of the cable
Cable diameter 6.0 mm
Cross section 8 x 0.25 mm²
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0.10 mm
Cable color black
Electrical properties
Cable Insulation resistance > 1000 Ω/Km
Operating voltage 300 V
Conductor resistance 79 Ω/Km (20°C)
Mechanical properties
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles > 2 million
Permitted acceleration 5 m/s²
Travel distance, horizontal at 5 m/s² -> 5 m
Travel distance, vertical at 5 m/s² -> 2 m
Travel speed at 5 m horizontal path -> 200 m/min
Thermal properties
Temperature range cable in move from/to -25 °C / 80 °C
Temperature range cable fixed from/to -50 °C / 80 °C
Other features
Halogen free yes
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  5. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
Bayonet NCC