Part no.: 09 3732 500 04
Female panel mount connector, Contacts: 4, shieldable, THT, IP67, PG 9, front fastened
M12-D, series 825, Automation Technology - Data Transmission
General features
MorelessPart no. | 09 3732 500 04 |
Connector design | Female panel mount connector |
Type standard | DIN EN 61076-2-101 |
Connector locking system | screw |
Termination | THT |
Degree of protection | IP67 |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 100 Mating cycles |
Weight (g) | 15.417 |
Customs tariff number | 85369010 |
Country of Origin | DE |
Electrical parameters
MorelessRated voltage | 250 V |
Rated impulse voltage | 2500 V |
Rated current | 4.0 A |
Insulation resistance | > 1010 Ω |
Pollution degree | 3 |
Transmission rate | CAT 5 |
Overvoltage category | II |
Insulating material group | II |
EMC compliance | shieldable |
Shield connection | Shielding plate |
Material
MorelessHousing material | CuZn (Brass nickel plated) |
Contact body material | PA |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Locking material | Zinc die-cast nickel-plated |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | 07fcfcc7-53db-4c7d-8a2f-2b22d560cd6b |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-09 |
ETIM 9.0 | EC003569 |
Security notices
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 50 cNm).